Trigger for initialization. Default is to initialize on boot.
ERRpulse
Pulse if initialization failed.
OKpulse
Pulse if initialization successful.
To use the node in your project you should have the wayland/scd30-co2-rh-temp library installed. Use the “File → Add Library” menu item in XOD IDE if you don’t have it yet. See Using libraries for more info.
C++ implementation
struct State {
};
{{ GENERATED_CODE }}
void evaluate(Context ctx) {
// The node responds only if there is an input pulse
if (!isInputDirty<input_INIT>(ctx))
return;
// Get a pointer to the `SCD30` class instance
auto airSensor = getValue<input_DEV>(ctx);
// Attempt to initialize SCD30 module; if attempt fails emit pulse from error port
if (!airSensor->begin()) {
emitValue<output_ERR>(ctx, 1);
return;
}
// Pulse that module initialized successfully
emitValue<output_OK>(ctx, 1);
}